Prototype of Water Turbidity Monitoring Device for Sanitation Hygiene Based on Minister of Health Regulation No 2/2023

Penulis

  • Nandang Gunawan Tunggal Waras Metrology and Instrumentation Diploma 3 Study Program Metrology and Instrumentation Academy
  • Muhammad Chasien Pratama Metrology and Instrumentation Diploma 3 Study Program Metrology and Instrumentation Academy
  • Dudi Adi Firmansyah Metrology and Instrumentation Diploma 3 Study Program Metrology and Instrumentation Academy
  • Ervanggis Minggar Kusumasari Metrology and Instrumentation Diploma 3 Study Program Metrology and Instrumentation Academy

Abstrak

Manual water quality monitoring in accordance with Minister of Health Regulation No. 2 of 2023 is urgently needed to detect early physical, chemical, microbiological, and radioactive contamination that could potentially endanger public health.. This water certainly has certain qualities, including its turbidity level. In accordance with Ministry of Health Regulation No.2/2023, the maximum turbidity limit for sanitary water is below 3 NTU. Therefore, a device is needed that can monitor the turbidity level of water practically. The purpose of this study is to design a prototype device for monitoring the turbidity value of sanitary hygiene water in accordance with Permenkes No. 2 of 2023. This study used the Analysis, Design, Development, Implementation, and Evaluation method. This method is expected to produce a structured and systematic approach to the development and design of the prototype that will be created. The prototype design process uses a TS 300B turbidity sensor to detect turbidity, NodeMCU ESP8266 as a microcontroller and IoT, and a 128x64 I2C OLED display. The application of IoT in this prototype is based on the use of a website to display and store measurement data. Testing was conducted on the TS 300B turbidity sensor on three samples with three repetitions, compared to the standard Nephelometric Turbidity Unit (NTU) solution. The test results showed an average accuracy and precision of 99.76% and 99.72%.  Currently, some of the detection device models on the market have an accuracy of between 0-200 NTU with the added feature of data connectivity, but they are relatively expensive.Therefore, in the future,  the role of IoT-based technology will be further optimized, with the aim of improving the quality of life for all

Referensi

Ageng S, Riska W. (2024). Dampak Krisis Air Bersih Terhadap Kesehatan Dan Strategi Dalam Mengatasi Permasalahan Di Perkampungan Ciwantani RW 17. Jurnal Ilmiah Ekonomi Dan Manajemen Vol.2, No.2 Februari 2024. DOI: https://doi.org/10.61722/jiem.v2i2.907

Akhiat. (2017). Pemanfaatan Air Kolong dalam Kegiatan Mandi, Cuci dan Kakus terhadap kejadian Penyakit Kulit. Jurnal Kesehatan Poltekkes Kemenkes RI Pangkalpinanginang, 5(2), 1–5. http://jurnal.poltekkespangkalpinang.ac.id/index.php/jkp/article/view/39

Cyfoeth Natural Resources. (2020). Turbidity of water What is Turbidity? 1–4. https://cdn.cyfoethnaturiol.cymru/media/694218/information-note-turbidity.pdf

Fakrizal, A. B., Romdania, Y., Wahono, E. P., & Herison, A. (2022). Kalibrasi Alat Ukur Sedimen Tersuspensi Berbasis Turbidity Sensor. Jrsdd, 10(4), 591–604.

Fernanda, A. F. (2020). Sistem Monitoring Kualitas Air Menggunakan Sensor Turbidity Metode Nephelometri Berbasis Raspberry PI 3. Telekontran : Jurnal Ilmiah Telekomunikasi, Kendali Dan Elektronika Terapan, 8(1), 23–29. https://doi.org/10.34010/telekontran.v8i1.3070

Kementerian Kesehatan. (2023). Permenkes No. 2 Tahun 2023. Kemenkes Republik Indonesia, 55, 1–175.

Kumala, A. R. (2024). Prototipe Sistem Rekam Data Alat-alat Ukur, Takar, Timbang dan Perlengkapannya Berbasis RFID. Telekontran : Jurnal Ilmiah Telekomunikasi, Kendali Dan Elektronika Terapan, 12(1), 38–49. https://doi.org/10.34010/telekontran.v12i1.12764

Maksalmina, M. B., Irwanto, D. A., Firmansyah, V., Adi, D., Yasri, B., Muslim, A., Sutanto, W., Gunawan, N., & Waras, T. (2024). Pengukuran Dimensi Nonkontak pada Objek Bola , Silinder , dan Kubus dengan Metode Triangulasi Menggunakan Laser Garis Non-Contact Dimension Measurement on Spherical , Cylindrical , and Cube Objects by Triangulation Method Using Line Laser. 12(1).

Prajnagra, R., Sumaryo, S., & Pangaribuan, P. (2021). Perancangan Sistem Monitoring Kelayakan Kualitas Air Bersih Metode Fuzzy Logic Design of Clean Water Quality Appropriateness Monitoring System With Multisensor for Hygiene Sanitation Water Using. Universitas Telkom, 8(2), 992–1000.

Pramesti, D. S., & Puspikawati, S. I. (2020). Analysis of Turbidity Test Bottled Drinking Water In Banyuwangi District. Preventif : Jurnal Kesehatan Masyarakat, 11(2), 75–85. https://doi.org/10.22487/preventif.v11i2.59

Reforma, B., Ma’arif, A., & Sunardi, S. (2022). Alat Pengukur Kualitas Air Bersih Berdasarkan Tingkat Kekeruhan dan Jumlah Padatan Terlarut. Jurnal Teknologi Elektro, 13(2), 66. https://doi.org/10.22441/jte.2022.v13i2.002

Sari, R., & Fata, A. (2024). Sistem Pemantauan dan Pengendalian Kekeruhan Berbasis Internet of Things Untuk Aplikasi Pada Proses Pengolahan Air Bersih. Jurnal Serambi Engineering, 9(2), 8598–8604.

Squyres, S. (1984). The History of Water on Mars. Annual Review of Earth and Planetary Sciences, 12(1), 83–106. https://doi.org/10.1146/annurev.earth.12.1.83

Sumarahinsih, A., Mahendra, S. A. E., & Nafsi, M. Z. D. (2023). Deteksi Kekeruhan untuk Memantau Kualitas Air Berbasis IoT. TELKA - Telekomunikasi Elektronika Komputasi Dan Kontrol, 9(1), 74–83. https://doi.org/10.15575/telka.v9n1.74-83

Udin, Hamrul, H., & Mansyur, M. F. (2021). Prototype Sistem Monitoring Kekeruhan Sumber Mata Air Berbasis Internet of Things. Journal of Applied Computer Science and Technology, 2(2), 66–72. https://doi.org/10.52158/jacost.v2i2.219

Wang, M., Shi, B., Catsamas, S., Kolotelo, P., & McCarthy, D. (2024). A Compact, Low-Cost, and Low-Power Turbidity Sensor for Continuous In Situ Stormwater Monitoring. Sensors, 24(12). https://doi.org/10.3390/s24123926

Diterbitkan

2025-12-26